CODESYS SoftMotion Light
CODESYS SoftMotion Light is a functionally restricted motion solution for single-axis motion. It allows you to control a large number of axes with one controller.
As motion is executed on the axes, both the controller and the fieldbus are unburdened. Only the status updates and motion commands are sent over the fieldbus. For commanding and monitoring the axes, the familiar PLCopen function blocks for motion control are implemented, such as MC_Home, MC_MoveAbsolute, and MC_ReadStatus. Simplified functionality is also provided.
The following table shows how CODESYS SoftMotion Light is different from CODESYS SoftMotion.
CODESYS SoftMotion | CODESYS SoftMotion Light | |
|---|---|---|
Required CPU resources | High | Low |
Required bus bandwidth / velocity | High | Low |
Required real-time capabilities (PLC and fieldbus) | High | Low |
Latency until new motion commands are in effect | Very low (new command started in same PLC cycle) | Medium (depends on configuration and fieldbus) |
Synchronization of several axes (cam, electronic gear, and CNC) and advanced functions, such as a touch probe. | Supported | Not supported |
Supported drives | Large and growing number of drivers for specific drives | Drives which support CiA 402 |
You can download the CODESYS SoftMotion Light from the CODESYS Store International or the CODESYS Store North America. There you will also find the data sheet for the product.